VWS-5/10/15 Smart Vibrating Wire Strain Gauge for Concrete Structure Monitoring

System Category
DL-SE
Signal Type
应变
Communication
Project-configured interface
Application Fit
Typical applications for this product
Industrial Equipment Monitoring
Monitor rotating machinery and industrial equipment condition including vibration, torque, shaft power, rotational speed, shaft torsional vibration, and operational condition trends.
Typical configuration reference
Cultural Heritage Monitoring System
Monitor crack evolution, structural vibration response, tilt, displacement, long-term deformation, rock-mass fissure evolution, weathering-related structural degradation, stability trends, and environmental or human-activity impact for protected heritage assets.
Typical configuration reference
Civil Infrastructure Structural Monitoring
Monitor civil infrastructure deformation, strain, vibration, displacement, tilt, cracks, settlement, GNSS movement, cable force, seismic response, and construction-stage structural behavior.
Typical configuration reference
Research & Engineering Testing
Capture modal response, vibration response, dynamic strain, torque, speed, temperature, pressure, force, displacement, and synchronized multi-channel data for engineering verification.
Typical configuration reference
Product Media
Product views and demonstration






Product Image and Application Context
Visual reference for VWS-5/10/15 Smart Vibrating Wire Strain Gauge for Concrete Structure Monitoring
Product images are used when available for RFQ evaluation and product recognition.
Primary Product Image

Product image configured for this product.
Application Context

Product image configured for this product.
应变
Typical project-specific installation deployment for project configuration.
Structural Monitoring
Typical project-specific installation deployment for project configuration.
Technical Specifications
Category
DL-SE
Measurement Range
>=3000 microstrain / >=3000 microstrain / >=3000 microstrain / >=3000 microstrain / >=3000 microstrain
Sampling Rate
0.016%F.S. or <=0.5 microstrain / same / same / same / same
Communication Protocol
Project-configured interface
Protection Level
Application-specific enclosure
Power Supply
Project-configured power supply
Application Tags
应变, Structural Monitoring
Installation Type
Project-specific installation
Gauge Length
65 mm / 100 mm / 150 mm / 100 mm / 150 mm
Effective / End Diameter
14 / 20 mm / 20 / 30 mm or 24 / 33 mm / 20 / 30 mm or 24 / 33 mm / 20 / 30 mm or 24 / 33 mm / 20 / 30 mm or 24 / 33 mm
Measurement Range
>=3000 microstrain / >=3000 microstrain / >=3000 microstrain / >=3000 microstrain / >=3000 microstrain
Resolution
0.016%F.S. or <=0.5 microstrain / same / same / same / same
Fitting / End Base Accuracy
0.1%F.S. / 0.5%F.S. / same / same / same / same
Temperature Range
-40 C to +80 C / same / same / same / same
Temperature Sensitivity
+/-0.1 C / same / same / same / same
Temperature Accuracy
+/-0.5 C / same / same / same / same
Temperature Correction Coefficient b
Approx. 12 microstrain/C / Approx. 12 microstrain/C / Approx. 12 microstrain/C / Approx. 13 microstrain/C / Approx. 13 microstrain/C
Smart Identification
>=1600 m / >=1600 m / >=1600 m / >=1600 m / >=1600 m
Smart Diagnosis
>=1600 m / >=1600 m / >=1600 m / >=1600 m / >=1600 m
Elastic Modulus Eg
Approx. 100-150 MPa / Approx. 150-800 MPa / Approx. 150-800 MPa / Approx. 800-1500 MPa / Approx. 800-1500 MPa
Water Pressure Resistance
0.5 MPa / 1 MPa / 0.5 MPa / 1 MPa / 0.5 MPa / 1 MPa / >=2 MPa / >=2 MPa
Insulation Resistance
>=50 MOhm / same / same / same / same
Material
Stainless steel / same / same / same / same
Engineering Applications
Where this DL product is applied
Typical Use Cases
Typical monitoring use cases
应变 monitoring applications
System Integration Context
Sensor, DAQ, and software context
Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.
Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.
Final configuration and calibration requirements are confirmed against the monitoring point schedule.