Dongling MonitoringIntegrated Testing / Sensing / Monitoring
DL-SE-196

VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring

DL-SE-196 VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring

System Category

DL-SE

Signal Type

压力

Communication

Project-configured interface

Product Media

Product views and demonstration

VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring main view
VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring detail view 1
VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring detail view 2
VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring detail view 3

Product Image and Application Context

Visual reference for VWE-Q Smart Vibrating Wire Earth Pressure Cell for Dam Slope Roadbed Soil Stress Monitoring

Product images are used when available for RFQ evaluation and product recognition.

Primary Product Image

DL-SE-196 Primary Product Image

Product image configured for this product.

Application Context

DL-SE-196 Application Context

Product image configured for this product.

压力

Typical project-specific installation deployment for project configuration.

Structural Monitoring

Typical project-specific installation deployment for project configuration.

Technical Specifications

Category

DL-SE

Measurement Range

0 to 350 / 700 / 1000 / 2000 / 5000 kPa

Sampling Rate

0.025%

Communication Protocol

Project-configured interface

Protection Level

Application-specific enclosure

Power Supply

Project-configured power supply

Application Tags

压力, Structural Monitoring

Installation Type

Project-specific installation

Model Series

VWE-0.35Q / VWE-0.7Q / VWE-1Q / VWE-2Q / VWE-5Q

Measurement Range

0 to 350 / 700 / 1000 / 2000 / 5000 kPa

Maximum Diameter D

100 / 156 mm

Pressure Plate Height H

21 to 24 mm

Resolution

0.025%

Fitting Accuracy

0.5%F.S.

Temperature Range

-40 C to +80 C

Temperature Sensitivity

+/-0.1 C

Temperature Accuracy

+/-0.5 C

Smart Identification

>=1600 m information recognition

Smart Diagnosis

>=1600 m fault diagnosis

Water Pressure Resistance

1.5 times measurement range

Over-Range Capacity

25% normal operation

Material

Stainless steel

Insulation Resistance

>=50 MOhm

Frequency Modulus

F = Hz2 x 10-3

Engineering Applications

Where this DL product is applied

Typical Use Cases

Typical monitoring use cases

压力 monitoring applications

System Integration Context

Sensor, DAQ, and software context

Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.

Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.

Final configuration and calibration requirements are confirmed against the monitoring point schedule.