Dongling MonitoringIntegrated Testing / Sensing / Monitoring
DL-SE-180

VWS-5/10F Smart Vibrating Wire Surface Strain Gauge for Steel Plate and Structure Monitoring

VWS-5/10F Smart Vibrating Wire Surface Strain Gauge is designed for long-term installation on the surface of hydraulic structures or other structures. It measures surface strain variation of the structure and synchronously measures the temperature at the installation point. The surface strain gauge adopts a full stainless steel integrated structure with anti-rotation, anti-bending, impact-resistant and drop-resistant design. It provides grounding lightning protection and can work underwater for long periods. Its low elastic modulus gives good follow-up performance with the measured structure and helps avoid disturbance to the original stress field.

DL-SE-180 VWS-5/10F Smart Vibrating Wire Surface Strain Gauge for Steel Plate and Structure Monitoring

System Category

DL-SE

Signal Type

应变

Communication

Project-configured interface

Product Media

Product views and demonstration

VWS-5/10F Smart Vibrating Wire Surface Strain Gauge for Steel Plate and Structure Monitoring main view
VWS-5/10F Smart Vibrating Wire Surface Strain Gauge for Steel Plate and Structure Monitoring detail view 1
VWS-5/10F Smart Vibrating Wire Surface Strain Gauge for Steel Plate and Structure Monitoring detail view 2

Product Image and Application Context

Visual reference for VWS-5/10F Smart Vibrating Wire Surface Strain Gauge for Steel Plate and Structure Monitoring

Product images are used when available for RFQ evaluation and product recognition.

Primary Product Image

DL-SE-180 Primary Product Image

Product image configured for this product.

Application Context

DL-SE-180 Application Context

Product image configured for this product.

Hydraulic structure surface strain monitoring

Typical project-specific installation deployment for project configuration.

Steel plate strain monitoring

Typical project-specific installation deployment for project configuration.

Dam structure monitoring

Typical project-specific installation deployment for project configuration.

Technical Specifications

Category

DL-SE

Measurement Range

>=3000 microstrain / >=3000 microstrain

Sampling Rate

0.016%F.S. or <=0.5 microstrain / 0.016%F.S. or <=0.5 microstrain

Communication Protocol

Project-configured interface

Protection Level

Application-specific enclosure

Power Supply

Project-configured power supply

Application Tags

Hydraulic structure surface strain monitoring, Steel plate strain monitoring, Dam structure monitoring, Bridge steel structure monitoring, Concrete and steel component monitoring, Long-term underwater structural monitoring

Installation Type

Project-specific installation

Model NO.

VWS-5F / VWS-10F

Product Name

Smart Vibrating Wire Surface Strain Gauge

Type

Surface Strain Gauge / Steel Plate Strain Gauge

Measurement Principle

Vibrating Wire

Application

Surface Strain Monitoring of Hydraulic Structures, Steel Plates and Other Structures

Gauge Length

65 mm for VWS-5F / 100 mm for VWS-10F

Measuring Range

>=3000 microstrain

Tension Range

>=1500 microstrain

Compression Range

>=1500 microstrain

Resolution

0.016%F.S. or <=0.5 microstrain

Accuracy

Fitting accuracy 0.1%F.S.; end base accuracy 0.5%F.S.

Temperature Range

-40°C to +80°C

Temperature Sensitivity

±0.1°C

Temperature Accuracy

±0.5°C

Temperature Correction Coefficient

Approx. 13 microstrain/°C

Smart Recognition

>=1600 m information recognition

Smart Diagnosis

>=1600 m fault diagnosis

Over-Range

25% normal operation

Elastic Modulus

Approx. 100~150MPa for VWS-5F; approx. 150~400MPa for VWS-10F

Water Pressure Resistance

0.5MPa

Insulation Resistance

>=50MΩ

Material

Stainless Steel

Accessories

Half Clamp for VWS-5F; Standard Clamp or T-Clamp with Wing Plate for VWS-10F

Compatible Automatic System

MCU Distributed Measurement Unit, GDA Full-Function Datalogger

Origin

China

Gauge Length

65 mm, not recommended / 100 mm

Effective Diameter / End Diameter

14 / 20 mm / 19.5 / 20 mm, 23 / 24 mm

Measuring Range

>=3000 microstrain / >=3000 microstrain

Tension Range

>=1500 microstrain / >=1500 microstrain

Compression Range

>=1500 microstrain / >=1500 microstrain

Resolution

0.016%F.S. or <=0.5 microstrain / 0.016%F.S. or <=0.5 microstrain

Fitting / End Base Accuracy

0.1%F.S. / 0.5%F.S. / 0.1%F.S. / 0.5%F.S.

Temperature Range

-40°C to +80°C / -40°C to +80°C

Temperature Sensitivity

±0.1°C / ±0.1°C

Temperature Accuracy

±0.5°C / ±0.5°C

Temperature Correction Coefficient

Approx. 13 microstrain/°C / Approx. 13 microstrain/°C

Smart Recognition

>=1600 m information recognition / >=1600 m information recognition

Smart Diagnosis

>=1600 m fault diagnosis / >=1600 m fault diagnosis

Over-Range

25% normal operation / 25% normal operation

Elastic Modulus

Approx. 100~150MPa / Approx. 150~400MPa

Water Pressure Resistance

0.5MPa / 0.5MPa

Insulation Resistance

>=50MΩ / >=50MΩ

Engineering Applications

Where this DL product is applied

Designed for long-term surface strain monitoring of hydraulic structures and other structures

Suitable for steel plate and structure surface installation

Synchronous temperature measurement at installation point

Full stainless steel integrated structure

Anti-rotation, anti-bending, impact-resistant and drop-resistant design

Grounding lightning protection

Low elastic modulus and good follow-up performance with measured structures

Does not disturb the original stress field

Typical Use Cases

Typical monitoring use cases

Hydraulic structure surface strain monitoring

Steel plate strain monitoring

Dam structure monitoring

Bridge steel structure monitoring

Concrete and steel component monitoring

Long-term underwater structural monitoring

Structural safety monitoring

Automatic strain monitoring networks

System Integration Context

Sensor, DAQ, and software context

Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.

Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.

Final configuration and calibration requirements are confirmed against the monitoring point schedule.