Dongling MonitoringIntegrated Testing / Sensing / Monitoring
DL-SE-193

VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation

VWP-G Smart Submersible Water Level Meter is designed for long-term installation in piezometer tubes of hydraulic structures or geotechnical slopes. It measures water level variation inside piezometers and can also be used for long-term monitoring of water level changes in reservoirs, rivers and lakes. The sensor adopts a full stainless steel structure and has a compact size of 24 x 136 mm, making it easy to install in piezometer tubes larger than 1 inch. It outputs RS485 digital signals, supports automatic barometric pressure compensation and synchronously measures the temperature at the embedded point.

DL-SE-193 VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation

System Category

DL-SE

Signal Type

水位

Communication

RS485 / RS485 / RS485 / RS485

Product Media

Product views and demonstration

VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation main view
VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation detail view 1
VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation detail view 2
VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation detail view 3

Product Image and Application Context

Visual reference for VWP-G Smart Submersible Water Level Meter with RS485 Output and Automatic Barometric Compensation

Product images are used when available for RFQ evaluation and product recognition.

Primary Product Image

DL-SE-193 Primary Product Image

Product image configured for this product.

Application Context

DL-SE-193 Application Context

Product image configured for this product.

Piezometer water level monitoring

Typical project-specific installation deployment for project configuration.

Hydraulic structure monitoring

Typical project-specific installation deployment for project configuration.

Geotechnical slope monitoring

Typical project-specific installation deployment for project configuration.

Technical Specifications

Category

DL-SE

Measurement Range

0-10 m / 0-20 m / 0-35 m / 0-70 m

Sampling Rate

0.02%F.S. / 0.02%F.S. / 0.02%F.S. / 0.02%F.S.

Communication Protocol

RS485 / RS485 / RS485 / RS485

Protection Level

Application-specific enclosure

Power Supply

Project-configured power supply

Application Tags

Piezometer water level monitoring, Hydraulic structure monitoring, Geotechnical slope monitoring, Reservoir water level monitoring, River water level monitoring, Lake water level monitoring

Installation Type

Project-specific installation

Model NO.

VWP-G Series

Product Name

Smart Submersible Water Level Meter

Type

Water Level Meter / Piezometer Water Level Sensor

Model Options

VWP-0.1G, VWP-0.2G, VWP-0.35G, VWP-0.7G

Measuring Range

0-10 m, 0-20 m, 0-35 m, 0-70 m

Resolution

0.02%F.S.

Measurement Accuracy

0.1%F.S.

Temperature Range

-40°C to +80°C

Temperature Sensitivity

±0.1°C

Barometric Correction

Automatic Compensation

Output Signal

RS485

Over-Range

25% normal operation

Max Diameter

24 mm

Length

136 mm

Material

Stainless Steel

Water Pressure Resistance

1.5 times of measuring range

Insulation Resistance

>=50MΩ

Structure

Water-permeable Part, Silicon Pressure Sensor, Digital Circuit, Sealed Housing, Observation Cable

Compatible Automatic System

MCU Distributed Measurement Unit, GDA Full-Function Datalogger

Application

Piezometer, Reservoir, River, Lake, Hydraulic Structure and Geotechnical Slope Monitoring

Origin

China

Measuring Range

0-10 m / 0-20 m / 0-35 m / 0-70 m

Max Diameter

24 mm / 24 mm / 24 mm / 24 mm

Length

136 mm / 136 mm / 136 mm / 136 mm

Resolution

0.02%F.S. / 0.02%F.S. / 0.02%F.S. / 0.02%F.S.

Measurement Accuracy

0.1%F.S. / 0.1%F.S. / 0.1%F.S. / 0.1%F.S.

Temperature Range

-40°C to +80°C / -40°C to +80°C / -40°C to +80°C / -40°C to +80°C

Temperature Sensitivity

±0.1°C / ±0.1°C / ±0.1°C / ±0.1°C

Barometric Correction

Automatic / Automatic / Automatic / Automatic

Output Signal

RS485 / RS485 / RS485 / RS485

Over-Range

25% normal operation / 25% normal operation / 25% normal operation / 25% normal operation

Material

Stainless Steel / Stainless Steel / Stainless Steel / Stainless Steel

Water Pressure Resistance

1.5 x range / 1.5 x range / 1.5 x range / 1.5 x range

Insulation Resistance

>=50MΩ / >=50MΩ / >=50MΩ / >=50MΩ

Equipment

Suggested Description

Calibration Equipment

Automatic Precision Pressure Calibration Bench

Calibration Instrument

Smart Digital Pressure Calibrator

Observation Cable

YSPT-4P hydraulic engineering cable

Cable Extension

Waterproof cable connector

Readout Unit

Full-function readout unit

Centralized Automatic Measurement

MCU distributed modular automatic measurement unit

Distributed Automatic Measurement

GDA full-function datalogger

Engineering Applications

Where this DL product is applied

Designed for long-term water level monitoring in piezometers, reservoirs, rivers and lakes

Suitable for hydraulic structures and geotechnical slope monitoring

Compact 24 x 136 mm stainless steel probe

Can be installed in piezometer tubes larger than 1 inch

RS485 digital output

Automatic barometric pressure compensation

Synchronous temperature measurement at embedded point

Smart identification information and smart fault diagnosis

Typical Use Cases

Typical monitoring use cases

Piezometer water level monitoring

Hydraulic structure monitoring

Geotechnical slope monitoring

Reservoir water level monitoring

River water level monitoring

Lake water level monitoring

Dam seepage and water pressure monitoring

Long-term groundwater level monitoring

System Integration Context

Sensor, DAQ, and software context

Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.

Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.

Final configuration and calibration requirements are confirmed against the monitoring point schedule.