Dongling MonitoringIntegrated Testing / Sensing / Monitoring
DL-SE-202

VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring

VWD-J Smart Vibrating Wire Joint Meter is designed for long-term installation inside or on the surface of concrete structures and other material structures. It measures the opening and closing displacement of expansion joints or peripheral joints, while synchronously measuring the temperature at the embedded point. The joint meter uses a VWD vibrating wire displacement meter as the sensing core and is assembled with supporting installation accessories. The instrument adopts a full stainless steel integrated structure with anti-rotation, anti-bending, impact-resistant and drop-resistant design. It provides grounding lightning protection and is suitable for long-term underwater operation.

DL-SE-202 VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring

System Category

DL-SE

Signal Type

位移

Communication

Project-configured interface

Product Media

Product views and demonstration

VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring main view
VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring detail view 1
VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring detail view 2
VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring detail view 3

Product Image and Application Context

Visual reference for VWD-J Smart Vibrating Wire Joint Meter for Expansion Joint and Peripheral Joint Monitoring

Product images are used when available for RFQ evaluation and product recognition.

Primary Product Image

DL-SE-202 Primary Product Image

Product image configured for this product.

Application Context

DL-SE-202 Application Context

Product image configured for this product.

Concrete structure expansion joint monitoring

Typical embedded or surface installation deployment for project configuration.

Peripheral joint opening monitoring

Typical embedded or surface installation deployment for project configuration.

Crack displacement monitoring

Typical embedded or surface installation deployment for project configuration.

Technical Specifications

Category

DL-SE

Measurement Range

0-20 mm / 0-50 mm / 0-100 mm

Sampling Rate

0.025%F.S. / 0.025%F.S. / 0.025%F.S.

Communication Protocol

Project-configured interface

Protection Level

Application-specific enclosure

Power Supply

Project-configured power supply

Application Tags

Concrete structure expansion joint monitoring, Peripheral joint opening monitoring, Crack displacement monitoring, Dam and hydraulic structure joint monitoring, Tunnel and culvert joint monitoring, Bridge and civil structure deformation monitoring

Installation Type

Embedded or Surface Installation

Model NO.

VWD-J

Product Name

Smart Vibrating Wire Joint Meter

Type

Joint Meter / Crack Meter / Displacement Sensor

Measurement Principle

Vibrating Wire

Sensor Core

VWD Vibrating Wire Displacement Meter

Application

Expansion Joint, Peripheral Joint, Crack and Structural Deformation Monitoring

Installation

Embedded or Surface Installation

Measurement Ranges

0-20 mm, 0-50 mm, 0-100 mm

Sensitivity

<=0.008 mm / <=0.02 mm / <=0.04 mm depending on range

Resolution

0.025%F.S.

Accuracy

Fitting accuracy 0.1%F.S.; end base accuracy 0.5%F.S.

Temperature Range

-40°C to +80°C

Temperature Sensitivity

±0.1°C

Temperature Accuracy

±0.5°C

Smart Recognition

>=1600 m information recognition

Smart Diagnosis

>=1600 m fault diagnosis

Over-Range

25% normal operation

Material

Stainless Steel

Water Pressure Resistance

>=1MPa

Insulation Resistance

>=50MΩ

Structure

Protective Pipe Seat, Protective Sleeve, Displacement Meter, Rear Connecting Ring, Observation Cable

Compatible Automatic System

MCU Distributed Measurement Unit, GDA Full-Function Datalogger

Origin

China

Instrument Diameter

30.5 mm / 24 mm / 24 mm

Instrument Length

337 mm / 373 mm / 325 mm

Measuring Range

0-20 mm / 0-50 mm / 0-100 mm

Sensitivity

<=0.008 mm / <=0.02 mm / <=0.04 mm

Resolution

0.025%F.S. / 0.025%F.S. / 0.025%F.S.

Fitting / End Base Accuracy

0.1%F.S. / 0.5%F.S. / 0.1%F.S. / 0.5%F.S. / 0.1%F.S. / 0.5%F.S.

Temperature Range

-40°C to +80°C / -40°C to +80°C / -40°C to +80°C

Temperature Sensitivity

±0.1°C / ±0.1°C / ±0.1°C

Temperature Accuracy

±0.5°C / ±0.5°C / ±0.5°C

Smart Recognition

>=1600 m information recognition / >=1600 m information recognition / >=1600 m information recognition

Smart Diagnosis

>=1600 m fault diagnosis / >=1600 m fault diagnosis / >=1600 m fault diagnosis

Over-Range

25% normal operation / 25% normal operation / 25% normal operation

Material

Stainless Steel / Stainless Steel / Stainless Steel

Water Pressure Resistance

>=1MPa / >=1MPa / >=1MPa

Insulation Resistance

>=50MΩ / >=50MΩ / >=50MΩ

Equipment

Suggested Description

Calibration Equipment

Displacement Sensor Calibration Frame

Calibration Instrument

Precision Grating Ruler

Observation Cable

YSPT-4P hydraulic engineering cable

Engineering Applications

Where this DL product is applied

Designed for long-term monitoring of expansion joints and peripheral joints

Suitable for concrete structures and other material structures

Supports embedded and surface installation

Measures joint opening displacement and deformation

Synchronous temperature measurement at embedded point

Uses VWD vibrating wire displacement meter as the sensing core

Full stainless steel integrated structure

Anti-rotation, anti-bending, impact-resistant and drop-resistant design

Typical Use Cases

Typical monitoring use cases

Concrete structure expansion joint monitoring

Peripheral joint opening monitoring

Crack displacement monitoring

Dam and hydraulic structure joint monitoring

Tunnel and culvert joint monitoring

Bridge and civil structure deformation monitoring

Embedded joint displacement monitoring

Surface joint displacement monitoring

System Integration Context

Sensor, DAQ, and software context

Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.

Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.

Final configuration and calibration requirements are confirmed against the monitoring point schedule.