GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication
GDA16 Series Multipurpose Datalogger is a full-function data acquisition unit designed for long-term online monitoring projects. It adopts a stand-alone structure and integrates measurement, transmission and power supply in one compact unit. The aluminum alloy enclosure provides protection against water, dust, ultraviolet exposure and electromagnetic interference, making it suitable for outdoor engineering monitoring environments. The GDA16 Series supports flexible 1, 4, 8 and 16-channel configurations. Each channel can be used for multiple types of sensor signals, including vibrating wire, differential resistance, resistance, current, voltage, switch and digital output signals. Sensor channels can be freely combined, and different sensor types can be connected to the same unit according to the project requirements.

System Category
DL-DAQ
Signal Type
全功能数据采集仪
Communication
RS485, 4G, LoRa / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional
Application Fit
Typical applications for this product
Industrial Equipment Monitoring
Monitor rotating machinery and industrial equipment condition including vibration, torque, shaft power, rotational speed, shaft torsional vibration, and operational condition trends.
Typical configuration reference
Cultural Heritage Monitoring System
Monitor crack evolution, structural vibration response, tilt, displacement, long-term deformation, rock-mass fissure evolution, weathering-related structural degradation, stability trends, and environmental or human-activity impact for protected heritage assets.
Typical configuration reference
Civil Infrastructure Structural Monitoring
Monitor civil infrastructure deformation, strain, vibration, displacement, tilt, cracks, settlement, GNSS movement, cable force, seismic response, and construction-stage structural behavior.
Typical configuration reference
Research & Engineering Testing
Capture modal response, vibration response, dynamic strain, torque, speed, temperature, pressure, force, displacement, and synchronized multi-channel data for engineering verification.
Typical configuration reference
Product Media
Product views and demonstration




Product Image and Application Context
Visual reference for GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication
Product images are used when available for RFQ evaluation and product recognition.
Primary Product Image

Product image configured for this product.
Application Context

Product image configured for this product.
Earth-rock dam long-term monitoring
Typical project-specific installation deployment for project configuration.
Slope deformation monitoring
Typical project-specific installation deployment for project configuration.
Tailings pond safety monitoring
Typical project-specific installation deployment for project configuration.
Software Platform
Software Platform & Analysis System
Structural health monitoring software for dynamic signal analysis, modal testing, fatigue evaluation, and multi-view engineering visualization in complete DAQ and monitoring systems.

Signal Processing Engine
FFT analysis, time-domain waveform processing, IIR/FIR filtering, wavelet analysis, and cepstrum tools.

Structural Dynamics Analysis
Modal analysis for EMA, OMA, and GVT workflows with FRF, ODS, and structural prediction support.

Data Analytics Engine
Rainflow counting, fatigue life evaluation, statistical analysis, integration, and signal preprocessing.

Visualization System
Real-time waveform, FFT spectrum, 2D/3D visualization, dashboards, meters, charts, and synchronized views.
Technical Specifications
Category
DL-DAQ
Measurement Range
GDA16系列
Sampling Rate
Project-configured measurement cycle
Communication Protocol
RS485, 4G, LoRa / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional
Protection Level
Not lower than IP65 / Not lower than IP65 / Not lower than IP65 / Not lower than IP65
Power Supply
Built-in Lithium Battery, Solar Power or AC Power
Application Tags
Earth-rock dam long-term monitoring, Slope deformation monitoring, Tailings pond safety monitoring, Foundation pit monitoring, Railway and highway engineering monitoring, Mine safety monitoring
Installation Type
Project-specific installation
Model NO.
GDA16 Series
Product Name
Multipurpose Datalogger / Data Acquisition Unit
Type
Full-Function Data Acquisition Instrument
Channel Options
1 / 4 / 8 / 16 Channels
Sensor Input
Vibrating Wire, Differential Resistance, Resistance, Current, Voltage, Switch, Digital Signal
Communication Interface
RS485
Communication Method
RS485, 4G, LoRa, Bluetooth, BeiDou Satellite, depending on configuration
Data Storage
16Mb >4000 records / 64Mb >30000 records, depending on configuration
Power Supply
Built-in Lithium Battery, Solar Power or AC Power
Input Voltage
7~30VDC
Battery Capacity
3.7V/6.4Ah, 3.7V/12.8Ah, 3.7V/25.6Ah, depending on channel configuration
GPS Positioning
Supported
Working Temperature
-40°C to +70°C
Working Humidity
<=95% at 40°C
Waterproof Rating
Not lower than IP65 with enclosure
Housing Material
Aluminum Alloy
Protocol
NGN encrypted protocol, Modbus, geological disaster platform protocol, water conservancy platform protocols, industry common protocols
Standard
DL/T 1134-2009 Dam Safety Monitoring Data Automatic Acquisition Device
Application
Dam Monitoring, Slope Monitoring, Tailings Pond Monitoring, Railway, Highway, Mine, Defense and Building Safety Monitoring
Origin
China
Channel Quantity
1 / 4 / 8 / 16
Sensor Input
Vibrating wire, digital signal / Vibrating wire, differential resistance, resistance, current, voltage, digital signal / Vibrating wire, differential resistance, resistance, current, voltage, digital signal / Vibrating wire, differential resistance, resistance, current, voltage, digital signal
Switch Input
External rain gauge input available / External rain gauge input available / External rain gauge input available / External rain gauge input available
Measurement Time
Approx. 3s, vibrating wire sensor example / Approx. 3s / Approx. 3s / Approx. 3s
Communication Distance
>2500 m, vibrating wire sensor example / >2500 m / >2500 m / >2500 m
Data Storage
16Mb, >4000 records / 64Mb, >30000 records / 64Mb, >30000 records / 64Mb, >30000 records
Communication Interface
RS485 / RS485 / RS485 / RS485
Communication Method
RS485, 4G, LoRa / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional
GPS Positioning
Supported / Supported / Supported / Supported
Input Voltage
7~30VDC / 7~30VDC / 7~30VDC / 7~30VDC
Working Temperature
-40°C to +70°C / -40°C to +70°C / -40°C to +70°C / -40°C to +70°C
Working Humidity
<=95% at 40°C / <=95% at 40°C / <=95% at 40°C / <=95% at 40°C
Reliability
MTBF >=10000h / MTBF >=10000h / MTBF >=10000h / MTBF >=10000h
Waterproof Rating
Not lower than IP65 / Not lower than IP65 / Not lower than IP65 / Not lower than IP65
Standard
DL/T 1134-2009 / DL/T 1134-2009 / DL/T 1134-2009 / DL/T 1134-2009
Vibrating Wire Frequency
400Hz~6000Hz / 0.001Hz / 0.1Hz
Vibrating Wire Temperature
-40°C~80°C / 0.01°C / 0.2°C
Differential Resistance Ratio
0.8000~1.2000 / 0.0001 / 0.0002
Differential Resistance Sum
0.02~120.02Ω / 0.0001Ω / 0.01Ω
Voltage
-5.000V~+5.000V / 0.0005%F.S. / 0.05%F.S.
Current
0.000~20.000mA / 0.001%F.S. / 0.05%F.S.
Small enclosure
9cm L x 11.5cm W x 6cm H
Engineering Applications
Where this DL product is applied
Integrated measurement, transmission and power supply in one unit
1, 4, 8 and 16-channel configurations available
Supports vibrating wire, differential resistance, resistance, current, voltage, switch and digital sensor signals
Mixed sensor access and flexible channel combination
RS485, 4G, LoRa, Bluetooth and BeiDou satellite communication options
Smart sensor recognition and fault diagnosis over cable length >=1600 m
Cloud one-click configuration and remote setup
Real-time acquisition, scheduled acquisition, data storage and automatic sleep
Typical Use Cases
Typical monitoring use cases
Earth-rock dam long-term monitoring
Slope deformation monitoring
Tailings pond safety monitoring
Foundation pit monitoring
Railway and highway engineering monitoring
Mine safety monitoring
Hydropower and water conservancy monitoring
Building construction safety monitoring
System Integration Context
Sensor, DAQ, and software context
Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.
Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.
Final configuration and calibration requirements are confirmed against the monitoring point schedule.