Dongling MonitoringIntegrated Testing / Sensing / Monitoring
DL-DAQ-165

GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication

GDA16 Series Multipurpose Datalogger is a full-function data acquisition unit designed for long-term online monitoring projects. It adopts a stand-alone structure and integrates measurement, transmission and power supply in one compact unit. The aluminum alloy enclosure provides protection against water, dust, ultraviolet exposure and electromagnetic interference, making it suitable for outdoor engineering monitoring environments. The GDA16 Series supports flexible 1, 4, 8 and 16-channel configurations. Each channel can be used for multiple types of sensor signals, including vibrating wire, differential resistance, resistance, current, voltage, switch and digital output signals. Sensor channels can be freely combined, and different sensor types can be connected to the same unit according to the project requirements.

DL-DAQ-165 GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication

System Category

DL-DAQ

Signal Type

全功能数据采集仪

Communication

RS485, 4G, LoRa / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional

Product Media

Product views and demonstration

GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication main view
GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication detail view 1
GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication detail view 2
GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication detail view 3

Product Image and Application Context

Visual reference for GDA16 Multipurpose Datalogger for Geotechnical Monitoring with 4G RS485 LoRa Bluetooth Communication

Product images are used when available for RFQ evaluation and product recognition.

Primary Product Image

DL-DAQ-165 Primary Product Image

Product image configured for this product.

Application Context

DL-DAQ-165 Application Context

Product image configured for this product.

Earth-rock dam long-term monitoring

Typical project-specific installation deployment for project configuration.

Slope deformation monitoring

Typical project-specific installation deployment for project configuration.

Tailings pond safety monitoring

Typical project-specific installation deployment for project configuration.

Software Platform

Software Platform & Analysis System

Structural health monitoring software for dynamic signal analysis, modal testing, fatigue evaluation, and multi-view engineering visualization in complete DAQ and monitoring systems.

DAQ / SHM / Modal / Visualization
Signal Processing Engine

Signal Processing Engine

FFT analysis, time-domain waveform processing, IIR/FIR filtering, wavelet analysis, and cepstrum tools.

Structural Dynamics Analysis

Structural Dynamics Analysis

Modal analysis for EMA, OMA, and GVT workflows with FRF, ODS, and structural prediction support.

Data Analytics Engine

Data Analytics Engine

Rainflow counting, fatigue life evaluation, statistical analysis, integration, and signal preprocessing.

Visualization System

Visualization System

Real-time waveform, FFT spectrum, 2D/3D visualization, dashboards, meters, charts, and synchronized views.

Technical Specifications

Category

DL-DAQ

Measurement Range

GDA16系列

Sampling Rate

Project-configured measurement cycle

Communication Protocol

RS485, 4G, LoRa / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional

Protection Level

Not lower than IP65 / Not lower than IP65 / Not lower than IP65 / Not lower than IP65

Power Supply

Built-in Lithium Battery, Solar Power or AC Power

Application Tags

Earth-rock dam long-term monitoring, Slope deformation monitoring, Tailings pond safety monitoring, Foundation pit monitoring, Railway and highway engineering monitoring, Mine safety monitoring

Installation Type

Project-specific installation

Model NO.

GDA16 Series

Product Name

Multipurpose Datalogger / Data Acquisition Unit

Type

Full-Function Data Acquisition Instrument

Channel Options

1 / 4 / 8 / 16 Channels

Sensor Input

Vibrating Wire, Differential Resistance, Resistance, Current, Voltage, Switch, Digital Signal

Communication Interface

RS485

Communication Method

RS485, 4G, LoRa, Bluetooth, BeiDou Satellite, depending on configuration

Data Storage

16Mb >4000 records / 64Mb >30000 records, depending on configuration

Power Supply

Built-in Lithium Battery, Solar Power or AC Power

Input Voltage

7~30VDC

Battery Capacity

3.7V/6.4Ah, 3.7V/12.8Ah, 3.7V/25.6Ah, depending on channel configuration

GPS Positioning

Supported

Working Temperature

-40°C to +70°C

Working Humidity

<=95% at 40°C

Waterproof Rating

Not lower than IP65 with enclosure

Housing Material

Aluminum Alloy

Protocol

NGN encrypted protocol, Modbus, geological disaster platform protocol, water conservancy platform protocols, industry common protocols

Standard

DL/T 1134-2009 Dam Safety Monitoring Data Automatic Acquisition Device

Application

Dam Monitoring, Slope Monitoring, Tailings Pond Monitoring, Railway, Highway, Mine, Defense and Building Safety Monitoring

Origin

China

Channel Quantity

1 / 4 / 8 / 16

Sensor Input

Vibrating wire, digital signal / Vibrating wire, differential resistance, resistance, current, voltage, digital signal / Vibrating wire, differential resistance, resistance, current, voltage, digital signal / Vibrating wire, differential resistance, resistance, current, voltage, digital signal

Switch Input

External rain gauge input available / External rain gauge input available / External rain gauge input available / External rain gauge input available

Measurement Time

Approx. 3s, vibrating wire sensor example / Approx. 3s / Approx. 3s / Approx. 3s

Communication Distance

>2500 m, vibrating wire sensor example / >2500 m / >2500 m / >2500 m

Data Storage

16Mb, >4000 records / 64Mb, >30000 records / 64Mb, >30000 records / 64Mb, >30000 records

Communication Interface

RS485 / RS485 / RS485 / RS485

Communication Method

RS485, 4G, LoRa / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional / RS485, 4G, Bluetooth, LoRa, BeiDou optional

GPS Positioning

Supported / Supported / Supported / Supported

Input Voltage

7~30VDC / 7~30VDC / 7~30VDC / 7~30VDC

Working Temperature

-40°C to +70°C / -40°C to +70°C / -40°C to +70°C / -40°C to +70°C

Working Humidity

<=95% at 40°C / <=95% at 40°C / <=95% at 40°C / <=95% at 40°C

Reliability

MTBF >=10000h / MTBF >=10000h / MTBF >=10000h / MTBF >=10000h

Waterproof Rating

Not lower than IP65 / Not lower than IP65 / Not lower than IP65 / Not lower than IP65

Standard

DL/T 1134-2009 / DL/T 1134-2009 / DL/T 1134-2009 / DL/T 1134-2009

Vibrating Wire Frequency

400Hz~6000Hz / 0.001Hz / 0.1Hz

Vibrating Wire Temperature

-40°C~80°C / 0.01°C / 0.2°C

Differential Resistance Ratio

0.8000~1.2000 / 0.0001 / 0.0002

Differential Resistance Sum

0.02~120.02Ω / 0.0001Ω / 0.01Ω

Voltage

-5.000V~+5.000V / 0.0005%F.S. / 0.05%F.S.

Current

0.000~20.000mA / 0.001%F.S. / 0.05%F.S.

Small enclosure

9cm L x 11.5cm W x 6cm H

Engineering Applications

Where this DL product is applied

Integrated measurement, transmission and power supply in one unit

1, 4, 8 and 16-channel configurations available

Supports vibrating wire, differential resistance, resistance, current, voltage, switch and digital sensor signals

Mixed sensor access and flexible channel combination

RS485, 4G, LoRa, Bluetooth and BeiDou satellite communication options

Smart sensor recognition and fault diagnosis over cable length >=1600 m

Cloud one-click configuration and remote setup

Real-time acquisition, scheduled acquisition, data storage and automatic sleep

Typical Use Cases

Typical monitoring use cases

Earth-rock dam long-term monitoring

Slope deformation monitoring

Tailings pond safety monitoring

Foundation pit monitoring

Railway and highway engineering monitoring

Mine safety monitoring

Hydropower and water conservancy monitoring

Building construction safety monitoring

System Integration Context

Sensor, DAQ, and software context

Confirm measurement range, cable length, mounting accessories, environmental conditions, and output interface before quotation.

Match the sensor or acquisition unit with the project data logger, communication gateway, power design, and monitoring platform.

Final configuration and calibration requirements are confirmed against the monitoring point schedule.